Nanofabrication platform

The ICN2 Nanofabrication Facility focuses on the design and development of nanofabrication methods and techniques for basic and applied research in nanoscience and nanotechnology. It provides researchers and students an extensive range of processing services to help them carry out their research activities. It also offers support, assistance and training to allow the researchers and other users to safely and efficiently operate the equipment available. The facility is designed to support the fabrication and characterisation of nanoscale materials and structures, and the integration of devices at all length scales. The facility’s mission is to provide high quality services to both internal and external users.

MISSION AND VISION

The Nanofabrication Facility is a cross-groups, general user facility, designed to support the ICN2 research effort. The facility is open to all trained personnel on a recharge basis, including ICN2 as well as external personnel. It is our mission to provide a state-of-the art facility for advanced device fabrication at the micro- and nano-scale. In addition to providing essential micro and nanofabrication capabilities for mainstream research on electronic, optoelectronic and 2D materials and devices, this facility is intended to facilitate the pursuit of research in emerging, interdisciplinary, and rapidly growing fields such as biomedical and biochemical lab-on-a-chip devices, heterogeneous integrated circuits, photonics and phononic devices and nanoscale science and technology. The Nanofabrication Facility aims to deliver outcomes that will have real impact for users, by ensuring that it is easy to access, agile in how it applies engineering expertise to respond quickly and accurately, and always seeking opportunities to enhance the quality of services that are available.

Facility

Leica Bond RX - Leica

Nanozoomer 2.0HT - Hamamatsu

Nanozoomer 2.0HT - Hamamatsu

Phenoigamer - Akoya

Phenoigamer - Akoya

Laser Microdissector - Leica

Laser Microdissector - Leica

CallenOne - Cellenion

CallenOne - Cellenion

Xenium - 10x Genomics

Xenium - 10x Genomics

MGI DNB-seq G400 Sequencer

MGI DNB-seq G400 Sequencer

TIMSTOF Ultra 2 - Bruker attached to Evosep One

TIMSTOF Ultra 2 - Bruker attached to Evosep One

HPLC alliance™ 2695 (Waters) con detectores 2996 UV/vis y desviación del índice de refracción 2414FPLC

Software

Empower

NeoFlex TOF TOF - Bruker

NeoFlex TOF TOF - Bruker

Thin film deposition

Thin film deposition is a process whereby materials - generally precious metals or oxides - are deposited onto a substrate or lithography sample. This can be achieved in a variety of ways such as sputtering, electroplating, evaporation, or CVD. ICN2 Nanofabrication Facility offers a range of different thin film deposition techniques and instruments, which are briefly explained here.

E-beam Evaporation

E-Beam evaporation is a physical vapor deposition (PVD) technique whereby an intense electron beam is generated from a filament and steered via electric and magnetic fields to strike the source material (e.g. pellets of Au) and vaporize it within a vacuum environment.

At some point as the source material is heated via this energy transfer its surface atoms will have sufficient energy to leave the surface, traverse the vacuum chamber and coat a substrate positioned above the evaporating material.

The advantage of this method over thermal evaporation is the possibility to use higher energies into the material to be evaporated, which leads to the formation of thin films with a higher density and consequently with an increased adhesion to the substrate. This method is also good for posterior lift-off processes, and is the way to obtain thin films with the highest purity. By using a multiple crucible E-beam gun, several different materials can be deposited without breaking the vacuum and thus avoiding interlayer contamination.

Bigfoot Spectral Sorter

The detection system is equipped with 5 lasers (346nm, 405nm, 488nm, 561nm, and 640nm) and a total of 53 detectors, 5 of which are dedicated to FSC and SSC scatter parameterization. It also has light depolarization filters for SSC scatter parameters on the blue laser.

The Bigfoot software allows working in both conventional and spectral modes and is housed within a class II biosafety cabinet with an aerosol extraction system featuring HEPA filters.

The cell sorting module consists of a jet-in air system and is equipped with 70, 100, 120, and 150 micrometer nozzles. Collection can be performed in 1.5mL eppendorf tubes, 5mL tubes, 15mL and 50mL falcon tubes. It is also possible to collect in various types of plates, allowing simultaneous 4-way sorting in a 96-well plate. Both the acquisition and collection ports are independently temperature controlled (4-37°C).

Characterization

Characterisation and imaging is a key phase of most fabrication processes as a test point in the development cycle. As such, ICN2 Nanofabrication Facility features a broad range of instruments which are capable of achieving high resolution images, topographical imaging, measurements of films stress as well as surface steps and roughness imaging, amongst others.

FEG-SEM

FEI Inspect F50: High resolution surface topography imaging.

Stylus Profilometer

A mechanical or stylus profilometer is a measuring instrument used to measure a surface's profile, in order to quantify its surface topography.

A diamond stylus tip is moved laterally across the sample for a specified distance and specified contact force while it is kept in contact with the sample.

The small variations in the vertical movement of the stylus according to the position are measured and recorded simultaneously during the scanning, revealing the topographical structure of the surface sample.

A typical profilometer can measure small vertical features ranging in height from few nanometres up to 1mm with nanometric accuracy. The radius of diamond stylus ranges from 20 nanometres to 50μm, and the horizontal resolution is controlled by the scan speed and data signal sampling rate. The stylus tracking force can range from less than 1 to 50 milligrams.

Optical 3D Profiler

Optical profilometry (OP) is a non-contact interferometric-based method for characterizing surface topography. A typical OP analysis provides 2D and 3D images of a surface, numerous roughness statistics, and feature dimensions.

Optical profiling uses the wave properties of light to compare the optical path difference between a test surface and a reference surface. Inside an optical interference profiler, a light beam is split, reflecting half the beam from a test material which is passed through the focal plane of a microscope objective and the other half of the split beam is reflected from the reference mirror. When the distance from the beam splitter to the reference mirror is the same distance as the beam splitter is from the test surface and the split beams are recombined, constructive and destructive interference occurs in the combined beam wherever the length of the light beams vary. This creates the light and dark bands known as interference fringes. Since the reference mirror is of a known flatness - that is, it is as close to perfect flatness as possible - the optical path differences are due to height variances in the test surface. This interference beam is focused into a digital camera, which sees the constructive interference areas as lighter and the destructive interference areas as darker. In the interference image each transition from light to dark represents one-half a wavelength of difference between the reference path and the test path. If the wavelength is known, it is possible to calculate height differences across a surface, in fractions of a wave. From these height differences, a surface measurement - a 3D surface map, if you will - is obtained.

Optical profilometry is suitable for numerous applications and sample types because it can accommodate many sample geometries, offering a wide range of possible analytical dimensions and a versatile Z-range, covering a broad range of potential surface roughness.

Optical microscope

The optical microscope, often referred to as light microscope, is a type of microscope which uses visible light and a system of lenses to magnify images of small samples.

It is a basic standard tool for surface inspection and metrology on very different types of samples and fields, from biology to materials science.

Technical specifications Manufacturer: Nikon Instruments Inc. Model: Eclipse LV100DA

Episcopic and diascopic illumination. Epi-illuminator with 100W halogen lamp (brightfield, darkfield, or polarized observations) Dia-illuminator with 50W halogen lamp (brightfield and polarized observation) Microscope objective lenses: 5x, 10x, 20x, 50x and 100x. Automatic x-y stage controller, 15x10mm. Microscope camera head (5M pixels CCD) for image and video acquisition. NIS-Elements Imaging Software

Packaging

Packaging is often the final step in making a nanofabrication device functional as a stand-alone device or in the context of an integrated system. The devices may need to be electrically connected to an interface via a process of gold or aluminium wire bonding. ICN2 Nanofabrication facility houses a wedge-wedge wire bonder.

Wedge Wire Bonder

Wire bonding is the method of making interconnections between an integrated circuit (IC) or other semiconductor device and its packaging during semiconductor device fabrication.

Wire bonding is generally considered the most cost-effective and flexible interconnect technology, and is used to assemble the vast majority of semiconductor packages.

The wedge bonding process utilizes ultrasonic energy and pressure to create a bond between the wire and the bond pad. The most predominant process for wedge bonding is a low temperature process or ambient temperature bonding, where aluminum wire is used to make the interconnection of the die and package. This “welding process” (either hot or cold) deforms the wire into a flat elongated shape of a wedge.

Provisional Contacts

Raúl Pérez Rodríguez |  raul.perez@icn2.cat  | 937 373 645 |  ORCID 

Raúl Pérez Rodríguez |  raul.perez@icn2.cat  | 937 373 645 |  ORCID 

Gustavo Ceballos | Head of Research Support Division - Instrumentation Unit |  gustavo.ceballos@icn2.cat  |  ORCID 

CERCA Institutes

Owners

Centres CERCA List

Equipments & Services Offered

The Nanofabrication Facility Lab is a 100m2 cleanroom type laboratory that offers equipment for the fabrication and characterization of micro- and nanodevices and structures. It is a specially designed and constructed room in which the air supply, air distribution, air filtration, materials of construction and operating procedures are regulated to control airbone particle concentrations to meet appropiate cleanliness levels. Our facility is classified as ISO Class 6 and 7 which means that there are at most 1,000 or 10,000 particles ≥ 0.5 µm per ft3, respectively The Facility is segmented in three dedicated rooms: ISO 6 room for Lithography processes and two ISO 7 rooms for etching and deposition processes. EQUIPMENTS Nanofabrication Facility provides a comprehensive user experience, housing instrumentation for many nanofabrication processes under the one roof. This allows users to take projects from concept through to prototype with ease. Key service areas include : Lithography Etching Thin film deposition Characterization Packaging

Molecular Factory Dynamic surfaces Antibacterial surfaces Conductive electrodes for OPV Light manipulation Dimensional nanometrology Graphene device technology for in vitro experiments Flexible graphene devices for in vivo preclinical evaluation Neural Implants Metamaterials Spintronics

Categorització

RIS3CAT domains & other

RIS3CAT Domains

CERCA GINYS Categories

GINYS-ICN2-003

Access procedure & Fares

Open . Reception is staffed between 9am and 5pm, Monday to Friday